Category : LS SWITCH PRODUCTS Brand : LS Switchgear With its compact dimensions, easy assembly can be done. It has a high performance and long-lasting electrical structure. It has a sealing structure that is resistant to environmental conditions. The switchgear, which is closed by the force of an electromagnetic coil and opened by the force of the spring, is called a contactor. Contactors are used to switch power circuits. They work on the same principle as relays. Their difference from the relay is that they are manufactured for larger currents. They do not provide any overcurrent or leakage current protection in the circuit, such as an automatic fuse, thermal relay or residual current relay. They just open and close the circuit. The circuit formed by the contact mechanisms of the contactor that opens and closes the circuit is called the power circuit of the contactor, and the electromagnetic coil circuit that moves the contacts is called the control circuit of the contactor. In an environment where we are not always present, the phase control relay immediately detects the negativities and cuts the control voltage of the motor and occurs in the motor and connected equipment. It protects from possible damage and malfunctions. Generally, they are more preferred in 3-phase motors. LSIS will be able to meet all your needs; offers a general, digital or premium Engine Protection solution. 3 Pole AC Power Contactors Model Rated Power (kW) Rated Current (A) Thermal Current Auxiliary Contact MC-6a AC24V 1a 3kW 7A 25A 1NO MC-6a AC220V 1a 1NO MC-6a AC24V 1b 1NC MC-6a AC220V 1b 1NC MC-9a AC24V 1a 4kW 9A 25A 1NO MC-9a AC220V 1a 1NO MC-9a AC24V 1b 1NC MC-9a AC220V 1b 1NC MC-12a AC24V 1a 5.5kW 12A 25A 1NO MC-12a AC220V 1a 1NO MC-12a AC24V 1a 1NC MC-12a AC220V 1a 1NK MC-18a AC24V 1a 7.5kW 18A 32A 1NO MC-18a AC220V 1a 1NO MC-18a AC24V 1b 1NK MC-18a AC220V 1b 1NK MC-9b AC24V 1a1b 4kW 9A 25A 1NO+1NC MC-9b AC220V 1a1b 1NA+ 1NC MC-12b AC24V 1a1b 5.5kW 12A 27A 1NO+1NC MC-12b AC220V 1a1b 1NO+1NC MC-18b AC24V 1a1b 7.5kW 18A 40A 1NO+1NK MC-18b AC220V 1a1b 1NO+1NC MC-22b AC24V 1a1b 11kW 22A 45A 1NO+1NC MC-22b AC220V 1a1b 1NO+1NK MC-32a AC24V 1a1b 15kW 32A 55A 1NO+1NK MC-32a AC220V 1a1b 1NO+1NK MC-32a AC24V 2a2b 15kW 32A 55A 2NA+2NK MC-32a 2NA+2a2b MC-40a AC24V 1a1b 18.5kW 40A 60A 1NO+1NK MC-40a AC220V 1a1b 1NO+1NK MC-40a AC24V 2a2b 18.5kW 40A 60A 2NO+2NK MC-40a AC220V 2a2b 2NA+2NK MC-5 0a AC24V 1a1b 22kW 50A 100A 1NO+1NC MC-50a AC220V 1a1b 1NO+1NC MC-50a AC24V 2a2b 22kW 50A 100A 2NO+2NK MC-50a AC220V 2a2b 2NO+2NK MC-65a AC24V 1a1b 30kW 65A MC-50a 1NO AC220V 1a1b 1NO+1NC MC-65a AC24V 2a2b 30kW 65A 115A 2NO+2NK MC-65a AC220V 2a2b 2NO+2NK MC-75a AC24V 1a1b 37kW 75A 125A 1NO+1NK MC-75a AC220V 1a1b 1NO+1 AC220V 2NAB 752 125A 2NO+2NK MC-75a AC220V 2a2b 2NA+2NK MC-85a AC24V 1a1b 45kW 85A 135A 1NO+1NK MC-85a AC220V 1a1b 1NO+1NK MC-85a AC24V 2a2b 45kW 85A 135A 2NA+2NK MC-852a AC220V MC-100a AC24V 1a1b 55kW 105A 160A 1NO+1NC MC-100a AC220V 1a1b 1NO+1NK MC-100a AC24V 2a2b 55kW 105A 160A 2NO+2NK MC-100a AC220V 2a2b 2NA+2NK MC-130a AC24V 1a1b 60kW+1 130MC 200 -130a AC220~240V 1a1b 1NO+1NC MC-130a AC100-240V, DC100-220V 1a1b 1NO+1NK MC-130a AC24V 2a2b 60kW 130A 200A 2NO+2NK MC-130a AC220~240V 2a2b 2NA+2NK MC-130a AC100-240V , DC100-220V 2a2b 2NO+2NK MC-150a AC24V 1a1b 75kW 150A 250A 1NO+1NC MC-150a AC220~240V 1a1b 1NO+1NC MC-150a AC100-240V , DC100-220V 1a1b 1NO+1NC MC-150a AC24V 2a2b 75kW 150A 250A 2NA+2NK MC-150a AC220~240V 2a2b 2NO+2NK MC-150a AC100-240V, DC100-220V 2a2b 2NA+2NK MC-185a AC100-240V, DC100-220V 2a2b 90kW 185A 300A 2NA+2NK MC-185a AC24~25V, DC24V 2a2b 2NA+2NK MC-225a AC100-240V, DC100-220V 2a2b 132kW 225A 350A 2NA+2NK MC-225a AC24~25V, DC24V 2a2b 2NK MC-265a AC100-240V, DC100-220V 2a2b 147kW 265A 400A 2NA+2NK MC-330a AC100-240V, DC100-220V 2a2b 160kW 330A 500A 2NA+2NK MC-400a AC100-240V, DC100-220V 2a2b 200kW 400A 520 +2NK MC-500a AC200-240V, DC200-220V 2a2b 265kW 500A 700A 2NA+2NK MC-630a AC200-240V, DC200-220V 2a2b 330kW 630A 900A 2NA+2NK MC-800a AC200-240V, DC200-220V 2a2b 1050A2b 800A 2NO+2NC 3-Pole DC Power Contactors Model Rated Power Rated Current Thermal Current Auxiliary Contact MC-9b/4 DC24V 1a1b 4kW 9A 25A 1NO+1NC MC-9b/4 DC48V 1a1b MC-12b/4 DC24V 1a1b 5.5kW 12A 25A 1NO +1NK MC-12b/4 DC48V 1a1b MC-18b/4 DC24V 1a1b 7.5kW 18A 40A 1NO+1NK MC-18b/4 DC48V 1a1b MC-22b/4 DC24V 1a1b 11kW 22A 45A 1NO+1NC MC-22b/4 DC48V 1a1b MC-32a/4 DC24V 1a1b 15kW 32A 55A 1NO+1NC MC-32a/4 DC48V 1a1b MC-40a/4 DC24V 1a1b 18.5kW 40A 60A 1NO+1NK MC-40a/4 DC48V 1a1b MC-50a/4 DC24V 1a1b 22kW 50A 100A 1NO+1NC MC-50a/4 DC48V 1a1b MC-65a/4 DC24V 1a1b 30kW 65A 115A 1NO+1NC MC-65a/4 DC48V 1a1b MC-75a/4 DC24V 1a1b 37kW 75A 125A 1NO+1NC MC-75a/4 DC48V 1a1b MC-85a/4 DC24V 1a1b 45kW 85A 135A 1NO+1NC MC-85a/4 DC48V 1a1b MC-100a/4 DC24V 1a1b 55kW 105A 160A 1NO+1NK MC-100a/4 DC48V 1a1b MC-130a/4 DC24V 1a1b 60kW 130A 200A 1NO+1NC MC-130a/4 DC48V 1a1b MC-150a/4 DC24V 1a1b 75kW 1
Warning: It is recommended that you do not make any payment (deposit, advance, etc.) before visiting the actual area (workplace, shop, etc.) where the advertiser offers his goods and services to the relevant parties and before receiving the goods and services you want to buy.