TRANSFORMER-FREE3 PHASE UNINTERRUPTED POWER SUPPLY DS-POWER

TRANSFORMER-FREE3 PHASE UNINTERRUPTED POWER SUPPLY DS-POWER, Electronic Systems
TRANSFORMER-FREE3 PHASE UNINTERRUPTED POWER SUPPLY DS-POWER, Electronic Systems

DS-POWER E (100-800kVA) High efficiency up to 95.5% in online mode and 99.6% in ECO mode kVA=kW (pf=1)IGBT and DSP technologyGalvanic isolation transformerHigh Overload CapacityGraphic LCD Display GENERAL FEATURES TECHNICAL SPECIFICATIONS With isolation transformer at its output It offers maximum performance with minimum loss in all applications thanks to its high efficiency up to 95.5% in online mode and kVA =kW(pf=1) value at its output regardless of ambient temperature. Thanks to the online double conversion technology developed with IGBT and DSP, it increases power quality and provides maximum protection for critical loads from military applications to data centers, industrial systems to medical applications. Thanks to Battery care technology, it provides maximum battery performance by protecting the battery life. Thanks to the output transformer, it provides an additional isolation between the DC busbar and the output loads. It provides wide flexibility in generator selections thanks to its high power factor, low THD, adjustable start time and soft start features at its input. It establishes an electronic interface connection with energy management systems within the Smart Grid application. It respects nature. MODEL DSE 100 DSE 120 DSE 160 DSE 200 DSE 250 DSE 300 DSE 400 DSE 500 DSE 600 DSE 800 Power (kVA) 100 120 160 200 250 300 400 500 600 800 INPUT Voltage 380/400/415 VAC 3F + N + Earth Frequency range 45-65Hz Power factor ≥ 0.99 THDI ≤ 3% Frequency tolerance ± 2% (from ± 1% to ± 5% front panel selectable) OUTPUT Power (kVA) 100 120 160 200 250 300 400 500 600 800 Active power ( kW) 100 120 160 200 250 300 400 500 600 800 Voltage 380/400/415 VAC 3F + N Voltage tolerance ± 1% (static), ± 5% (dynamic 10ms) Voltage THD < 1% linear load / < 3% linear Efficiency at non-load (100% load) ≥ 95% Frequency tolerance 0.05% (on battery operation) Frequency 50Hz / 60Hz Crest factor 3:1 Overload capacity 60min at 110% load; 10 minutes at 125% load; 1min at 150% load Battery Type VRLA AGM, GEL, NiCd Number of batteries 40x12V (480 VDC) Ripple current Zero, “0” Charge voltage compensation 0.5 V x ºC GENERAL Net weight (kg) 730 785 865 990 1090 1520 1670 2500 2830 3950 Dimensions (mm) WxDxH 800x850x1900 1000x850x1900 1500x1000x1900 2100x1000x1900 3200x1000x1900 Alarm signal Dry contacts (adjustable) Remote control Bypass (adjustable) Communication Dual RS232 + dry contacts + 2 slots for communication interface Ambient temperature 0ºC – 40ºC Efficiency 95% ECO mode efficiency > 99% RH < 95% (non-condensing) Color RAL7016 Noise level 63-68 dBA 70-72 dBA Protection class IP20 (higher protection class optional) Standards EN62040-I-I ; EMC:EN62040-2 Classification (according to IEC62040-3) (Voltage frequency independent) VFI-SS-111

Warning: It is recommended that you do not make any payment (deposit, advance, etc.) before visiting the actual area (workplace, shop, etc.) where the advertiser offers his goods and services to the relevant parties and before receiving the goods and services you want to buy.