DUPLEX HOUSING

DUPLEX HOUSING, Building Construction
DUPLEX HOUSING, Building Construction

It is mounted on a pre-prepared concrete base with steel bolts. H profiles are also used in interior partition joints. In the plans prepared in such a way that the widths and lengths are multiples of 125.5 mm, there are 3 different walls: solid wall panel not exceeding 90 kg weight, wall panel with window and wall panel with door, standard wall thickness (8+44+8mm=60 mm). is happening. CARRIER SYSTEMS; The frame system, which is an earthquake resistant system, is preferred in buildings that contain all the features of the lightweight prefabricated technique. It is produced based on 100 kg/m2 snow load and 90 km/h wind speed, 1st degree earthquake conditions and 3 climate zones. Standard parts, steel column and truss and 40x60x1.5 mm profile purlins are used. All connections are made with steel bolts and nuts and are primed against corrosion. EXTERIOR WALLS; Insulated against heat and sound on the outer surface, non-flammable, not affected by humidity and water, 8 mm thick, 1250x2500 mm in size, ~1300kg/m3 density, B1 DIN4102 Part1 (non-flammable), thermal conductivity coefficient (^10'Cdry):0.15W/Mk , cemented particle board (BETOPAN). Insulated against heat and sound on its inner surface, non-flammable, not affected by humidity and water, 8 mm thick, 1250x2500 mm in size, ~1300kg/m3 density, B1 DIN4102 Part1 (non-flammable), thermal conductivity coefficient (^10'Cdry):0.15W/Mk , cemented particle board (BETOPAN). Between the two surface coatings, B-1 class polystyrene rigid foam with a thickness of 44 mm and a density of 20kg/m3 is used. The heat transmission coefficient is k-0.40 kcal/m2°Ch or k=0.44 W/m²K. The outer wall thickness is 60 mm and the height is 2500 mm. INTERIOR WALLS; Insulated against heat and sound on both surfaces, non-flammable, not affected by humidity and water, 8 mm thick, 1250x2500 mm in size, ~1300kg/m3 density, B1 DIN4102 Part1 (non-flammable), thermal conductivity coefficient (^10'Cdry):0.15W/ Mk, cemented particle board (BETOPAN). Between the two surface coatings, B-1 class polystyrene rigid foam with a thickness of 44 mm and a density of 20kg/m3 is used. The heat transmission coefficient is k=0.50 kcal/m2°Ch or 0.52 W/m²K. The inner wall thickness is 60 mm. ROOF COVERING; In buildings with H joint system, the roof is made in two ways: 1) Roof; It has a light steel truss system and the roof purlins consist of 40x60x1.5 mm profiles. Building truss height and eave dimensions are determined according to the project. Profile is designed as 11 mm thick OSB on purlin, 3 mm thick waterproofing membrane as roof sealing material over OSB, and Shingle as roof covering over membrane. Shingle color is red or green. For roof insulation, 80 mm glass wool is laid. PVC Vinyl is used as the eaves underlay material. Rain gutters and landings are made of PVC. 2) Roof; It has a light steel truss system and the roof purlins consist of 40x60x1.5 mm profile purlins. Roof covering is 0.50 mm thick, 27 mm pitched DIN EN 10142, natural 27/200 form galvanized trapezoidal sheet metal or red/green corrugated. Bent eaves of 200 mm wide DKP sheet are made around the building. CEILING COVERING; Ceiling; It is a suspended ceiling and 12.5 mm thick white gypsum board is used as ceiling covering. As thermal insulation, gypsum board is covered with DIN4102 and TS EN 13501-1, fireproof Class A roll glass wool with a thickness of 100 mm and a density of 14 kg/m3. The heat transmission coefficient is k=0.32 kcal/m2°Ch or 0.37 W/m²K. DOORS; Exterior doors: Steel door with metal frame, door handle and mortise locks are fitted. Interior doors: American panel door with metal door frame, 820x1950 mm in size, is used, metal door handles and mortise locks are installed. WINDOWS; PVC joinery is double glazed with double glass, glass thickness is 4+10.5+4 mm, glasses are fitted and Egepen brand is used. If requested as an extra; window joinery is made in color and mosquito nets are attached to the opening wings of the windows. MEZZANINE; It is designed from specially bent profiles cut from galvanized sheets. Betopan with a thickness of 16 mm is used as an intermediate layer. Floor coverings on Betopan are made by the buyer. STAIRS; It is manufactured from metal stairs, and its steps and railings are made. ELECTRICAL INSTALLATION; The electrical installation is drawn by us and a globe lamp is used for lighting. Sockets and switches are placed in appropriate places. All installation cables are antigron cables and are laid on the surface. (Lamp cables are 2x1.5 mm thick, socket cables are 3x2.5 mm thick.) Grounding system is available, grounding rod is taken by the customer and assembled by us. A fuse box is placed by attaching fuses. The supply of the electricity meter and the electricity subscription belong to the customer. All electrical materials are TSE certified and guaranteed. SANITARY INSTALLATION; Si

Warning: It is recommended that you do not make any payment (deposit, advance, etc.) before visiting the actual area (workplace, shop, etc.) where the advertiser offers his goods and services to the relevant parties and before receiving the goods and services you want to buy.